Deckma | Omd11 Manual Exclusive
Two independent potential-free relays (individually adjustable from 1 to 15 ppm). Response Time: Less than 5 seconds. 2. Component Layout and System Design
The manual is typically structured to guide the user through each stage of the equipment's lifecycle, from installation to advanced troubleshooting. While the OMD-11 is no longer in production, it is still fully supported by DECKMA and authorized service centers, meaning technical support remains available.
The OMD-11 is known for its compact design and improved "solids suppression," which prevents non-oil particles (like iron oxide) from triggering false alarms. deckma omd11 manual
The Deckma OMD-11 is a core industrial oil content meter. It monitors oil-in-water concentration in marine bilge water. The device ensures strict compliance with MARPOL requirements. This comprehensive guide covers the technical specifications, installation steps, calibration rules, and troubleshooting procedures found in the official manual. 🛠️ Technical Specifications
: Designed to meet the IMO Resolution MEPC. 60(33) requirements for monitoring oil content in marine environments. Component Layout and System Design The manual is
Fix : Cycle the power supply off and on. Contact service if it persists. Meaning : Optical path is heavily blocked or fouled.
: Utilizes scattered light measurement to accurately calculate oil concentration while suppressing interference from solids (like iron oxide). Key Specifications The Deckma OMD-11 is a core industrial oil content meter
Weighs approximately 3.5 kg with an IP 65 protection rating. Installation & Operational Essentials
Flush the cell; clean the glass tube mechanically; check for sample pump cavitation.