Xycd60 Manual (GENUINE × REVIEW)

| Parameter | Meaning | Example Setting (12V Lead‑Acid) | | :-------- | :------------------------------ | :------------------------------- | | | Upper voltage limit (overcharge protection) | 14.4 V (charging stop) | | dn | Lower voltage limit (over‑discharge protection) | 10.5 V (load disconnect) | | OP | Maximum on‑time (minutes:seconds). Set 00:00 to disable. | 01:30 | | dOP | Delay‑on time (seconds) before restarting after a cycle completes | 030 (30 seconds) | | FOP | Discharge mode only . Forces relay ON for 0–10 seconds to stabilise load | 003 (3 seconds) |

If you have a handheld, high-lumen flashlight likely powered by an 18650 battery, you have this version. The official manufacturer's documentation is rarely included, but all the information you need is here in a structured format.

Use the UP and DOWN buttons to set the required voltage values.

The battery’s voltage is below 6 V, above 60 V, or the battery type is incompatible. xycd60 manual

A: It indicates that the current voltage is outside the programmed UP and dn limits, and the relay is currently off.

If you are looking for specific wiring diagrams for your battery type, tell me:

for about 3 seconds to enter the parameter setting interface. Short press SET to cycle through the parameters: UP : Upper limit voltage. dn : Lower limit voltage. OP : Conduction time (00:00 to 99:59, or "----" to disable). dOP : Delayed conduction time (0–999 seconds). FOP : Forced start time (0–10 seconds) in discharge mode. Use UP/DOWN buttons to adjust the values. Press and hold SET again to save and exit. Voltage Percentage Calculation | Parameter | Meaning | Example Setting (12V

Despite its advanced features and capabilities, the Xycd60 device may occasionally encounter issues or errors. Here are some common problems and their solutions:

If you have a specific XY-CD60 model (e.g., XY-CD60L, XY-CD60H, or a different variant), let me know and I’ll adjust the details.

A: This is usually due to voltage fluctuations at the threshold. Increase the difference between your UP and dn settings to create a larger hysterisis band. Forces relay ON for 0–10 seconds to stabilise

Why readers should consult the manual

Important Note: The XY-CD60 is not a battery charger or voltage converter. It is a voltage-controlled switch that completes or breaks a circuit using an onboard mechanical relay to manage external power sources or loads. Technical Specifications Specifications & Value XY-CD60 / XY-CD60L Control Voltage Range DC 6V to 60V Compatible Batteries Lead-acid, Lithium-ion, LiFePO4, Ni-MH, Ni-Cd Maximum Current Rating 10A to 20A (depending on variant; 10A standard relay limit) Display Type

Long press DOWN to turn on/off the display backlight to save energy. ON : Screen turns off after 5-10 minutes.